User: Guest  Login
Document type:
Konferenzbeitrag
Author(s):
Groher, M.; Padoy, N.; Jakobs, T. F.; Navab, N.
Title:
New CTA Protocol and 2D-3D Registration Method for Liver Catheterization
Abstract:
2D-3D registration for angiographic liver interventions is an unsolved problem mainly because of two reasons. First, a suitable protocol for Computed Tomography Angiography (CTA) to contrast liver arteries is not used in clinical practice. Second, an adequate registration algorithm which addresses the difficult task of aligning deformed vessel structures has not been developed yet. We address the first issue by introducing an angiographic CT scanning phase and thus create a strong link between r...     »
Keywords:
CAMP,MICCAI,RegVis,feature-based,2D-3D registration,ANGIO,AngioReg
Editor:
Larsen, R.; Nielsen, M.; Sporring, J.
Book / Congress title:
Proceedings of MICCAI 2006
Organization:
MICCAI Society
Publisher:
Springer
Publisher address:
Copenhagen, Denmark
Year:
2006
Pages:
873--881
Bookseries title:
Lncs 4190
Bookseries volume:
1