In the Firenwood project four different test series were performed to investigate the behaviour of glued-in metallic fasteners under the influence of heat, in particular for a fire load. Test series 2 exposes test specimens with glued-in rods to the Standard Fire Curve for 60 minutes. No mechanical load is applied. The aim is to generate thermal parameters for numerical simulations and to investigate the influence of different setups and thermal protection measures on the temperature development within the glued joint.
Within test series 2, a distinction is made between three different test setups. The test specimens of test series 2.1 and 2.2 are exposed to fire on only one side, while the test specimens of test series 2.3 are exposed to fire on four sides.
«
In the Firenwood project four different test series were performed to investigate the behaviour of glued-in metallic fasteners under the influence of heat, in particular for a fire load. Test series 2 exposes test specimens with glued-in rods to the Standard Fire Curve for 60 minutes. No mechanical load is applied. The aim is to generate thermal parameters for numerical simulations and to investigate the influence of different setups and thermal protection measures on the temperature development...
»