Abstract:
This work investigates the current distribution in parallel-connected battery cells. The first study quantifies the factors influencing the electrical contact measurement and proposes optimizations for the connection design. The second presents a novel method for the current measurement in parallel connected cells that minimizes the effects of parasitic elements. A final study quantifies the temperature and resistance sensitivity factors for three cell technologies.
Translated abstract:
Diese Arbeit untersucht die Stromaufteilung in Parallelgeschalteten Batteriezellen. Die erste Studie quantifiziert die Einflussfaktoren der elektrischen Kontaktmessung, und schlägt Optimierungen für das Verbindungsdesign vor. In der zweiten wird eine Methode für die Parallelschaltung von Zellen vorgestellt, die die Auswirkungen parasitärer Elemente minimiert. In einer letzten Studie werden die Temperatur- und Widerstandsempfindlichkeitsfaktoren für drei Zelltechnologien quantifiziert.