User: Guest  Login
Original title:
Parallel Configuration of Battery Cells
Original subtitle:
Determining Influencing Factors of an Inhomogeneous Current Distribution
Translated title:
Parallelverschaltung von Batteriezellen
Translated subtitle:
Bestimmung der Einflussfaktoren für eine Inhomogene Stromaufteilung
Author:
Jocher, Philipp
Year:
2024
Document type:
Dissertation
Faculty/School:
TUM School of Engineering and Design
Institution:
Elektrische Energiespeichertechnik (Prof. Jossen)
Advisor:
Jossen, Andreas (Prof. Dr.)
Referee:
Jossen, Andreas (Prof. Dr.); Schmidt, Jan Philipp (Prof. Dr.)
Language:
en
Subject group:
ELT Elektrotechnik
TUM classification:
ELT 972
Abstract:
This work investigates the current distribution in parallel-connected battery cells. The first study quantifies the factors influencing the electrical contact measurement and proposes optimizations for the connection design. The second presents a novel method for the current measurement in parallel connected cells that minimizes the effects of parasitic elements. A final study quantifies the temperature and resistance sensitivity factors for three cell technologies.
Translated abstract:
Diese Arbeit untersucht die Stromaufteilung in Parallelgeschalteten Batteriezellen. Die erste Studie quantifiziert die Einflussfaktoren der elektrischen Kontaktmessung, und schlägt Optimierungen für das Verbindungsdesign vor. In der zweiten wird eine Methode für die Parallelschaltung von Zellen vorgestellt, die die Auswirkungen parasitärer Elemente minimiert. In einer letzten Studie werden die Temperatur- und Widerstandsempfindlichkeitsfaktoren für drei Zelltechnologien quantifiziert.
WWW:
https://mediatum.ub.tum.de/?id=1738827
Date of submission:
22.04.2024
Oral examination:
27.09.2024
File size:
13634048 bytes
Pages:
123
Urn (citeable URL):
https://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:91-diss-20240927-1738827-1-8
Last change:
28.10.2024
 BibTeX