Benutzer: Gast  Login
Dokumenttyp:
Journal Article
Autor(en):
Kampfer, Severin; Dobiasch, Sophie; Combs, Stephanie E; Wilkens, Jan J
Titel:
Development of a PTV margin for preclinical irradiation of orthotopic pancreatic tumors derived from a well-known recipe for humans.
Abstract:
In human radiotherapy a safety margin (PTV margin) is essential for successful irradiation and is usually part of clinical treatment planning. In preclinical radiotherapy research with small animals, most uncertainties and inaccuracies are present as well, but according to the literature a margin is used only scarcely. In addition, there is only little experience about the appropriate size of the margin, which should carefully be investigated and considered, since sparing of organs at risk or no...     »
Zeitschriftentitel:
Z Med Phys
Jahr:
2023
Volltext / DOI:
doi:10.1016/j.zemedi.2023.03.005
PubMed:
http://view.ncbi.nlm.nih.gov/pubmed/37225604
Print-ISSN:
0939-3889
TUM Einrichtung:
Klinik und Poliklinik für RadioOnkologie und Strahlentherapie (Prof. Combs)