PURPOSE: The aim of this study was the development of a simple procedure to calculate functional kinetic parameters from the plantar pressure distribution measurement which is used in many orthopaedic practices and clinics as a standard measurement device. The special purpose is the comparison of functional parameters between datasets taken before and after a surgical operation, for example the correction of a hallux valgus. METHOD: In the gait laboratory, pressure distribution measurements were...     »