User: Guest  Login
Original title:
X-ray Phase-Contrast Imaging at a Compact Laser-Driven Synchrotron Source
Translated title:
Röntgen-Phasenkontrast-Bildgebung an einer kompakten lasergetriebenen Synchrotronquelle
Author:
Schleede, Simone
Year:
2013
Document type:
Dissertation
Faculty/School:
Fakultät für Physik
Advisor:
Pfeiffer, Franz (Prof. Dr.)
Referee:
Pfeiffer, Franz (Prof. Dr.); Ruth, Ronald D. (Prof. Dr.)
Language:
en
Subject group:
PHY Physik
Keywords:
X-ray imaging, grating interferometry, phase-contrast imaging, mammography, inverse Compton X-rays
Abstract:
In this thesis, a series of phase-contrast imaging experiments at laser-driven X-ray sources is presented. The advantages of using compact high brilliance sources are assessed and radiological questions, which benefit from phase-contrast imaging, are investigated. As a result of the present work, these sources are considered to have a strong potential of complementing conventional synchrotrons in high performance imaging experiments. New applications, which are shown to significantly profit from...     »
Translated abstract:
Die vorliegende Arbeit beschreibt Phasenkontrast-Bildgebungsexperimente an lasergetriebenen Röntgenquellen. Es werden Vorteile der Nutzung kompakter, hochbrillianter Quellen, sowie radiologische Fragestellungen, die von Phasenkontrast-Bildgebung profitieren, beleuchtet. Im Ergebnis wurde in dieser Arbeit gezeigt, dass lasergetriebene Quellen in brillanten Experimenten komplementär zu konventionellen Synchrotronquellen sind. Die Lungenemphysem-Diagnostik und die Brust-Tomosynthese sind neue Anwen...     »