Benutzer: Gast  Login
Titel:

A low-noise high-dynamic range time-domain emi measurement system for CISPR band E

Dokumenttyp:
Konferenzbeitrag
Art des Konferenzbeitrags:
Vortrag / Präsentation
Autor(en):
Hoffmann, C.; Russer, P.
Abstract:
In this paper, a broadband time-domain EMI measurement system for measurements from 9 kHz to 18 GHz is presented that allows for compliant EMI measurements in CISPR Band E. Combining ultra-fast analogto- digital-conversion and real-time digital signal processing on a field-programmable-gate-array (FPGA) with ultrabroadband multi-stage down-conversion, scan times can be reduced by several orders of magnitude in comparison to a traditional heterodyne EMI-receiver. The ultra-low system noi...     »
Kongress- / Buchtitel:
URSI Conference Kleinheubach 2010
Kongress / Zusatzinformationen:
Miltenberg, Germany, Oct 04-06, 010
Verlag / Institution:
Copernicus Publications on behalf of the URSI Landesausschuss in der Bundesrepublik Deutschland e.V.
Jahr:
2010
Quartal:
4. Quartal
Jahr / Monat:
2010-10
Monat:
Oct
Reviewed:
nein
Sprache:
en
Volltext / DOI:
doi:10.5194/ars-9-309-2011
WWW:
http://www.adv-radio-sci.net/9/309/2011/ars-9-309-2011.pdf