Comparison of auto-fluorescence and tetracycline fluorescence for guided bone surgery of medication-related osteonecrosis of the jaw: a randomized controlled feasibility study.

Dokumenttyp:
Journal Article
Autor(en):
Ristow, O; Otto, S; Geis, C; Kehl, V; Berger, M; Troeltzsch, M; Koerdt, S; Hohlweg-Majert, B; Freudlsperger, C; Pautke, C
Abstract:
Recent studies have indicated that bone shows auto-fluorescence under an appropriate fluorescence lamp. The aim of this preliminary study was to compare the success rates of the established tetracycline fluorescence-guided bone surgery with auto-fluorescence-guided bone surgery in the treatment of medication-related osteonecrosis of the jaw (MRONJ). Forty patients suffering from MRONJ were referred for surgical treatment and were divided randomly into two groups: auto-fluorescence (n=20) or tetr...     »