Benutzer: Gast  Login
Titel:

Pretherapeutic Comparative Dosimetry of 177Lu-rhPSMA-7.3 and 177Lu-PSMA I&T in Patients with Metastatic Castration-Resistant Prostate Cancer.

Dokumenttyp:
Journal Article
Autor(en):
Feuerecker, Benedikt; Chantadisai, Maythinee; Allmann, Anne; Tauber, Robert; Allmann, Jakob; Steinhelfer, Lisa; Rauscher, Isabel; Wurzer, Alexander; Wester, Hans-Jürgen; Weber, Wolfgang Andreas; D'Alessandria, Calogero; Eiber, Matthias
Abstract:
Radiohybrid prostate-specific membrane antigen (rhPSMA) ligands allow for labeling with 18F and radiometals for endoradiotherapy. rhPSMA-7.3 has been designated as a lead compound with promising preclinical data for 177Lu-rhPSMA-7.3, which has shown higher tumor uptake than 177Lu-PSMA I&T. In this retrospective analysis, we compared pretherapeutic clinical dosimetry data of both PSMA ligands. Methods: Six patients with metastatic castration-resistant prostate cancer underwent both 177Lu-rhPSMA-7.3 and 177Lu-PSMA I&T pretherapeutic dosimetry. Whole-body scintigraphy was performed at 1 h, 4 h, 24 h, 48 h, and 7 d after injection. Regions of interest covering the whole body, organs, bone marrow, and tumor lesions were drawn for each patient. Absorbed doses for individual patients and pretherapeutic applications were calculated using OLINDA/EXM. To facilitate the comparison of both ligands, we introduced the therapeutic index (TI), defined as the ratio of mean pretherapeutic doses to tumor lesions over relevant organs at risk. Results: Mean whole-body pretherapeutic effective doses for 177Lu-rhPSMA-7.3 and 177Lu-PSMA I&T were 0.12 ± 0.07 and 0.05 ± 0.03 Sv/GBq, respectively. Mean absorbed organ doses for 177Lu-rhPSMA-7.3 and 177Lu-PSMA I&T were, for example, 1.65 ± 0.28 and 0.73 ± 0.18 Gy/GBq for the kidneys, 0.19 ± 0.09 and 0.07 ± 0.03 Gy/GBq for the liver, 2.35 ± 0.78 and 0.80 ± 0.41 Gy/GBq for the parotid gland, and 0.67 ± 0.62 and 0.30 ± 0.27 Gy/GBq for the bone marrow, respectively. Tumor lesions received mean absorbed doses of 177Lu-rhPSMA-7.3 and 177Lu-PSMA I&T of 6.44 ± 6.44 and 2.64 ± 2.24 Gy/GBq, respectively. The mean TIs for the kidneys were 3.7 ± 2.2 and 3.6 ± 2.2 for 177Lu-rhPSMA-7.3 and 177Lu-PSMA I&T, respectively, and those for the bone marrow were 15.2 ± 10.2 and 15.1 ± 10.2 for 177Lu-rhPSMA-7.3 and 177Lu-PSMA I&T, respectively. Conclusion: Pretherapeutic clinical dosimetry confirmed preclinical results of mean absorbed doses for tumors that were 2-3 times higher for 177Lu-rhPSMA-7.3 than for 177Lu-PSMA I&T. Absorbed doses to normal organs also tended to be higher for 177Lu-rhPSMA-7.3, resulting overall in similar average TIs for both radiopharmaceuticals with considerable interpatient variability. 177Lu-rhPSMA-7.3 has promise for a therapeutic efficacy similar to that of 177Lu-PSMA I&T at smaller amounts of injected activity, simplifying radiation safety measurements (especially for large patient numbers or dose escalation regimens).
Zeitschriftentitel:
J Nucl Med
Jahr:
2022
Band / Volume:
63
Heft / Issue:
6
Seitenangaben Beitrag:
833-839
Volltext / DOI:
doi:10.2967/jnumed.121.262671
PubMed:
http://view.ncbi.nlm.nih.gov/pubmed/34531260
Print-ISSN:
0161-5505
TUM Einrichtung:
Klinik und Poliklinik für Nuklearmedizin; Urologische Klinik und Poliklinik
 BibTeX