PURPOSE: To study the potential of viscoelastic parameters such as liver stiffness, loss tangent (marker of viscous properties) and viscoelastic dispersion to detect hepatic inflammation by in-vivo and ex-vivo MR elastography (MRE) at low and high vibration frequencies.
METHODS: 15 patients scheduled for liver tumor resection surgery were prospectively enrolled in this IRB-approved study and underwent multifrequency in-vivo MRE (30-60Hz) at 1.5-T prior to surgery. Immediately after liver resection, tumor-free tissue specimens were examined with ex-vivo MRE (0.8-2.8 kHz) at 0.5-T and histopathologic analysis including NAFLD activity score (NAS) and inflammation score (I-score) as sum of histological sub-features of inflammation.
RESULTS: In-vivo, in regions where tissue samples were obtained, the loss tangent correlated with the I-score (R = 0.728; p = 0.002) and c-dispersion (stiffness dispersion over frequency) correlated with lobular inflammation (R = -0.559; p = 0.030). In a subgroup of patients without prior chemotherapy, c-dispersion correlated with I-score also in the whole liver (R = -0.682; p = 0.043). ROC analysis of the loss tangent for predicting the I-score showed a high AUC for I ≥ 1 (0.944; p = 0.021), I ≥ 2 (0.804; p = 0.049) and I ≥ 3 (0.944; p = 0.021). Ex-vivo MRE was not sensitive to inflammation, whereas strong correlations were observed between fibrosis and stiffness (R = 0.589; p = 0.021), penetration rate (R = 0.589; p = 0.021), loss tangent (R = -0.629; p = 0.012), and viscoelastic model parameters (spring-pot powerlaw exponent, R = -0.528; p = 0.043; spring-pot shear modulus, R = 0.589; p = 0.021).
CONCLUSION: Our results suggest that c-dispersion of the liver is sensitive to inflammation when measured in-vivo in the low dynamic range (30-60Hz), while at higher frequencies (0.8-2.8 kHz) viscoelastic parameters are dominated by fibrosis.
«
PURPOSE: To study the potential of viscoelastic parameters such as liver stiffness, loss tangent (marker of viscous properties) and viscoelastic dispersion to detect hepatic inflammation by in-vivo and ex-vivo MR elastography (MRE) at low and high vibration frequencies.
METHODS: 15 patients scheduled for liver tumor resection surgery were prospectively enrolled in this IRB-approved study and underwent multifrequency in-vivo MRE (30-60Hz) at 1.5-T prior to surgery. Immediately after liver resecti...
»