Benutzer: Gast  Login
Titel:

Malpositioned olecranon fracture tension-band wiring results in proximal radioulnar synostosis.

Dokumenttyp:
Journal Article
Autor(en):
Willinger, Lukas; Lucke, Martin; Crönlein, Moritz; Sandmann, Gunther H; Biberthaler, Peter; Siebenlist, Sebastian
Abstract:
Tension-band wiring (TBW) is a well-established fixation technique for two-part, transverse fracture types of the olecranon. However, complication rates up to 80 % are reported. By reporting on the enormous impact on the patient if failed the aim of the present report was to emphasize the importance of correct K wire positioning in TBW.We present the case of a 49-year-old woman who suffered from a radioulnar synostosis of the forearm due to malpositioned K wires after TBW treatment. The patient...     »
Zeitschriftentitel:
Eur J Med Res
Jahr:
2015
Band / Volume:
20
Heft / Issue:
1
Seitenangaben Beitrag:
87
Volltext / DOI:
doi:10.1186/s40001-015-0184-7
PubMed:
http://view.ncbi.nlm.nih.gov/pubmed/26514829
Print-ISSN:
0949-2321
TUM Einrichtung:
Klinik und Poliklinik für Unfallchirurgie