mediaTUM
Universitätsbibliothek
Technische Universität München
Benutzer: Gast
Login
de
en
mediaTUM Gesamtbestand
Hochschulbibliographie
2024
(5277)
2023
(7956)
2022
(8729)
2021
(8938)
2020
(8191)
2019
(8865)
2018
(8662)
2017
(8686)
2016
(8831)
2015
(8220)
Fakultäten
(7451)
Architektur
(121)
Bau Geo Umwelt
(924)
Chemie
(473)
Elektrotechnik und Informationstechnik
(1251)
Informatik
(503)
Maschinenwesen
(1271)
Mathematik
(185)
Medizin
(591)
Else Kröner-Fresenius-Zentrum für Ernährungsmedizin - Klinik für Ernährungsmedizin
(33)
Institut für Allgemeine Pathologie und Pathologische Anatomie
(84)
Institut für Allgemeinmedizin (keine SAP-Zuordnung!)
(16)
Institut für Arbeitsmedizin - LMU
Institut für Biologische Bildgebung
Institut für Diabetesforschung
Institut für Experimentelle Onkologie und Therapieforschung
(17)
Institut für Geschichte, Theorie und Ethik der Medizin
(1)
Institut für Humangenetik
(84)
Institut für Klinische Chemie und Pathobiochemie
(21)
Institut für Medizinische Mikrobiologie, Immunologie und Hygiene
(35)
Institut für Medizinische Statistik und Epidemiologie
(65)
Institut für Molekulare Immunologie
(9)
Institut für Neurowissenschaften
(12)
Institut für Pharmakologie und Toxikologie
(14)
Institut für Radiologie
(123)
Institut für Rechtsmedizin - LMU
Institut für Strahlenbiologie
Institut für Toxikologie und Umwelthygiene
Institut für Virologie
(48)
Institut für Zellbiologie des Nervensystems
(8)
Molekulare Allergologie
(50)
Physik
(212)
Sport- und Gesundheitswissenschaften
(175)
TUM School of Education
(133)
Wirtschaftswissenschaften
(334)
Wissenschaftszentrum Weihenstephan
(1280)
Integrated Research Centers
(497)
Zentrale Einrichtungen
(272)
2014
(7148)
2013
(6755)
2012
(5774)
2011
(5563)
2010
(5427)
2009
(4595)
2008
(4109)
1989 - 2007
Elektronische Prüfungsarbeiten
Open Access Publikationen
Forschungsdaten
TUM.University Press
Sammlungen
Projekte
Einrichtungen
mediaTUM Gesamtbestand
Hochschulbibliographie
2015
Fakultäten
Medizin
Institut für Radiologie
Zurück
Zurück zum Anfang der Trefferliste
Dauerhafter Link zum angezeigten Objekt
Titel:
The need for T2 correction on MRS-based vertebral bone marrow fat quantification: implications for bone marrow fat fraction age dependence.
Dokumenttyp:
Journal Article
Autor(en):
Dieckmeyer, Michael; Ruschke, Stefan; Cordes, Christian; Yap, Samuel P; Kooijman, Hendrik; Hauner, Hans; Rummeny, Ernst J; Bauer, Jan S; Baum, Thomas; Karampinos, Dimitrios C
Abstract:
Vertebral bone marrow fat quantification using single-voxel MRS is confounded by overlapping water-fat peaks and the difference in T2 relaxation time between water and fat components. The purposes of the present study were: (i) to determine the proton density fat fraction (PDFF) of vertebral bone marrow using single-voxel multi-TE MRS, addressing these confounding effects; and (ii) to investigate the implications of these corrections with respect to the age dependence of the PDFF. Single-voxel MRS was performed in the L5 vertebral body of 86 subjects (54 women and 32 men). To reliably extract the water peak from the overlying fat peaks, the mean bone marrow fat spectrum was characterized based on the area of measurable fat peaks and an a priori knowledge of the chemical triglyceride structure. MRS measurements were performed at multiple TEs. The T2 -weighted fat fraction was calculated at each TE. In addition, a T2 correction was performed to obtain the PDFF and the T2 value of water (T2w ) was calculated. The implications of the T2 correction were investigated by studying the age dependence of the T2 -weighted fat fractions and the PDFF. Compared with the PDFF, all T2 -weighted fat fractions significantly overestimated the fat fraction. Compared with the age dependence of the PDFF, the age dependence of the T2 -weighted fat fraction showed an increased slope and intercept as TE increased for women and a strongly increased intercept as TE increased for men. For women, a negative association between the T2 value of bone marrow water and PDFF was found. Single-voxel MRS-based vertebral bone marrow fat quantification should be based on a multi-TE MRS measurement to minimize confounding effects on PDFF determination, and also to allow the simultaneous calculation of T2w , which might be considered as an additional parameter sensitive to the composition of the water compartment. Copyright © 2015 John Wiley & Sons, Ltd.
Zeitschriftentitel:
NMR Biomed
Jahr:
2015
Band / Volume:
28
Heft / Issue:
4
Seitenangaben Beitrag:
432-9
Sprache:
eng
Volltext / DOI:
doi:10.1002/nbm.3267
PubMed:
http://view.ncbi.nlm.nih.gov/pubmed/25683154
Print-ISSN:
0952-3480
TUM Einrichtung:
Else Kröner-Fresenius-Zentrum für Ernährungsmedizin - Klinik für Ernährungsmedizin; Fachgebiet Neuroradiologie (Prof. Zimmer)
BibTeX
Vorkommen:
mediaTUM Gesamtbestand
Einrichtungen
Schools
TUM School of Medicine and Health
Departments
Clinical Medicine
Klinik für Ernährungsmedizin (Prof. Hauner)
2015
mediaTUM Gesamtbestand
Hochschulbibliographie
2015
Fakultäten
Medizin
Institut für Radiologie
mediaTUM Gesamtbestand
Einrichtungen
Schools
TUM School of Medicine and Health
Departments
Clinical Medicine
Institut für Diagnostische und Interventionelle Radiologie (Prof. Makowski)
Abteilung für Diagnostische und Interventionelle Neuroradiologie (Prof. Zimmer)
Professur für Neuroradiologie (Prof. Zimmer)
2015
mediaTUM Gesamtbestand
Hochschulbibliographie
2015
Fakultäten
Medizin
Else Kröner-Fresenius-Zentrum für Ernährungsmedizin - Klinik für Ernährungsmedizin