Abstract:
PURPOSE: Accurate and precise renal dosimetry during 177 Lu-labeled prostate-specific membrane antigen (PSMA) radioligand therapy is crucial for therapy decisions. Sampling schedules for estimating the necessary time-integrated activity coefficients (TIACs) are not optimized and standardized for clinical practice. Therefore, a simulation study to determine optimal sampling schedules (OSSs) was performed on 13 virtual 177 Lu-PSMA I&T; therapy patients. METHOD: A total of 880 clinically feasible sam...     »