User: Guest  Login
Document type:
Zeitschriftenaufsatz
Author(s):
Maier, A.; Gee, M.W.; Reeps, C.; Pongratz, J.; Eckstein, H.-H.; Wall, W.A.
Title:
A comparison of diameter, wall stress and rupture potential index for abdominal aortic aneurysm rupture risk prediction
Abstract:
An abdominal aortic aneurysm (AAA) is a balloon-like dilation of the aorta, which is potentially fatal in case of rupture. Computational finite element (FE) analysis is a promising approach to a more accurate and patient-specific rupture risk prediction. AAA wall strength and rupture potential index (RPI) calculation are implemented in our FE software. Static structural FE simulations are performed on n = 30 non-ruptured asymptomatic, n = 9 non-ruptured symptomatic, and n = 14 ruptured AAAs. We...     »
Keywords:
abdominal aortic aneurysm, diameter criterion, finite elements, rupture potential index, wall stress.
Dewey Decimal Classification:
620 Ingenieurwissenschaften
Journal title:
Annals of Biomedical Engineering
Year:
2010
Journal volume:
38
Month:
Jan
Journal issue:
10
Pages contribution:
3124-3134
Reviewed:
ja
Language:
en
Fulltext / DOI:
doi:10.1007/s10439-010-0067-6
Status:
Verlagsversion / published
Semester:
SS 10
Format:
Text
 BibTeX