User: Guest  Login
Title:

Extent of Cathodic Reaction on Epoxy Coated Rebar with Partially Disbonded Coating

Document type:
Konferenzbeitrag
Contribution type:
Textbeitrag / Aufsatz
Author(s):
Kessler, S.; Sagüés, A. A.; Lau, K.
Pages contribution:
Document ID NACE-2017-9469
Absract (alternative):
Corrosion of epoxy coated rebar (ECR) in chloride exposed concrete can be enabled by the oxygen reduction cathodic reaction taking place on steel exposed by coating breaks. The total cathodic current would be expected to increase if the reaction locus were to extend into crevices formed at disbonded coating regions around coating breaks. To examine the possible amount of this effect, distress in the form of controlled surface breaks was created on production samples of ECR, some of which were f...     »
Keywords:
cathodic disbondment, electrode area, Epoxy-coated reinforcement
Dewey Decimal Classification:
620 Ingenieurwissenschaften
Editor:
NACE International
Book / Congress title:
CORROSION 2017
Congress (additional information):
http://www.nace.org/cstm/PaperTrail/Authors/Submission.aspx?id=c4cfab76-9310-e611-8011-0050569a4cdc
Date of congress:
26-30 March, 2017
Year:
2017
Reviewed:
ja
Language:
en
Publication format:
Print
WWW:
https://www.onepetro.org/conference-paper/NACE-2017-9469
 BibTeX