User: Guest  Login
Document type:
Zeitschriftenaufsatz
Author(s):
Eggl, Elena; Dierolf, Martin; Achterhold, Klaus; Jud, Christoph; Günther, Benedikt; Braig, Eva; Gleich, Bernhard; Pfeiffer, Franz
Title:
The Munich Compact Light Source: initial performance measures
Abstract:
While large-scale synchrotron sources provide a highly brilliant monochromatic X-ray beam, these X-ray sources are expensive in terms of installation and maintenance, and require large amounts of space due to the size of storage rings for GeV electrons. On the other hand, laboratory X-ray tube sources can easily be implemented in laboratories or hospitals with comparatively little cost, but their performance features a lower brilliance and a polychromatic spectrum creates problems with beam hard...     »
Journal title:
Journal of Synchrotron Radiation
Year:
2016
Journal volume:
23
Pages contribution:
1137-1142
Reviewed:
ja
Language:
en
Fulltext / DOI:
doi:10.1107/s160057751600967x
Publisher:
International Union of Crystallography (IUCr)
Date of publication:
22.07.2016
 BibTeX