Benutzer: Gast  Login
Dokumenttyp:
Comparative Study; Journal Article; Article
Autor(en):
Herrmann, K; Takei, T; Kanegae, K; Shiga, T; Buck, AK; Altomonte, J; Schwaiger, M; Schuster, T; Nishijima, K; Kuge, Y; Tamaki, N
Titel:
Clinical value and limitations of [11C]-methionine PET for detection and localization of suspected parathyroid adenomas.
Abstract:
PURPOSE: The aim of this study was to assess the clinical value of [(11)C]methionine-PET (MET-PET) for detection and localization of parathyroid adenomas in patients without prior thyroidectomy. METHODS: A retrospective analysis of patients with suspected parathyroid adenomas undergoing imaging with MET-PET was performed. Prior thyroidectomy was an exclusion criterion. Forty-one patients with a total of 49 MET-PET scans were included. MET-PET consisted of whole-body images obtained 15-20 min aft...     »
Zeitschriftentitel:
Mol Imaging Biol
Jahr:
2009
Band / Volume:
11
Heft / Issue:
5
Seitenangaben Beitrag:
356-63
Sprache:
eng
Volltext / DOI:
doi:10.1007/s11307-009-0205-4
PubMed:
http://view.ncbi.nlm.nih.gov/pubmed/19340488
Print-ISSN:
1536-1632
TUM Einrichtung:
Klinik und Poliklinik für Nuklearmedizin
 BibTeX