Sherif, HM; Saraste, A; Weidl, E; Weber, AW; Higuchi, T; Reder, S; Poethko, T; Henriksen, G; Casebier, D; Robinson, S; Wester, HJ; Nekolla, SG; Schwaiger, M
Titel:
Evaluation of a novel (18)F-labeled positron-emission tomography perfusion tracer for the assessment of myocardial infarct size in rats.
Abstract:
BACKGROUND: The goal of this study was to evaluate a new (18)F-labeled positron-emission tomography (PET) perfusion tracer, (18)F BMS747158-02, for the assessment of myocardial infarct (MI) size. METHODS AND RESULTS: Wistar rats were studied 24 hours after ligation of the left coronary artery either permanently (n=15) or transiently (n=16) for 30 minutes. Seven nonoperated rats were studied as controls. The rats were injected with 37 MBq of (18)F BMS747158-02 and imaged with a small animal PET scanner for 20 minutes. Polar maps were generated for measurement of PET defect size, and left ventricular systolic and diastolic volumes were assessed in gated images. As a reference, MI size was determined by 2,3,5-triphenyltetrazolium chloride staining of left ventricular tissue samples. Permanent or transient ligation of the left coronary artery produced transmural or subendocardial MI of variable sizes, respectively. In normal rats, PET imaging demonstrated intense and homogeneous uptake of (18)F BMS747158-02 throughout the myocardium. After ligation, sharply defined perfusion defects were present. Throughout the imaging period, the defect size correlated closely with the MI size either after permanent (r=0.88; P<0.01; mean difference, 1.86%) or transient (r=0.92; P<0.01; mean difference, 2.16%) ligation of the left coronary artery. Moreover, reduction of left ventricular systolic function measured with PET correlated with the MI size (r=-0.81; P<0.01; n=23). CONCLUSIONS: Myocardial (18)F BMS747158-02 PET imaging provides excellent image quality and uptake properties, enabling accurate evaluation of MI size and left ventricular function in rats. It is a promising technique for evaluation of MI size in clinical trials.
Zeitschriftentitel:
Circ Cardiovasc Imaging
Jahr:
2009
Band / Volume:
2
Heft / Issue:
2
Seitenangaben Beitrag:
77-84
Sprache:
eng
Volltext / DOI:
doi:10.1161/CIRCIMAGING.108.815423
PubMed:
http://view.ncbi.nlm.nih.gov/pubmed/19808572
Print-ISSN:
1941-9651
TUM Einrichtung:
Klinik und Poliklinik für Nuklearmedizin
 BibTeX