OBJECTIVES: The goal of this study was to identify the risk factors for prolonged length of stay (LOS) in the intensive care unit (ICU) after a bidirectional cavopulmonary shunt (BCPS) procedure and its impact on the number of deaths.
METHODS: In total, 556 patients who underwent BCPS between January 1998 and December 2019 were included in the study.
RESULTS: Eighteen patients died while in the ICU, and 35 died after discharge from the ICU. Reduced ventricular function was significantly associated with death during the ICU stay (P = 0.002). In patients who were discharged alive from the ICU, LOS in the ICU [hazard ratio (HR) 1.04, 95% confidence interval (CI) 1.02-1.06; P < 0.001] and a dominant right ventricle (HR 2.41, 95% CI 1.03-6.63; P = 0.04) were independent risk factors for death. Receiver operating characteristic analysis identified a cut-off value for length of ICU stay of 19 days. Mean pulmonary artery pressure (HR 1.03, 95% CI 1.01-1.05; P = 0.04) was a significant risk factor for a prolonged ICU stay.
CONCLUSIONS: Prolonged LOS in the ICU with a cut-off value of 19 days after BCPS was a significant risk factor for mortality. High pulmonary artery pressure at BCPS was a significant risk factor for a prolonged ICU stay.