Sollmann, Nico; Mei, Kai; Riederer, Isabelle; Schön, Simon; Kirschke, Jan S; Meyer, Bernhard; Zimmer, Claus; Baum, Thomas; Noël, Peter B
Titel:
Low-Dose MDCT of Patients With Spinal Instrumentation Using Sparse Sampling: Impact on Metal Artifacts.
Abstract:
OBJECTIVE. The purpose of our study was to evaluate simulated sparse-sampled MDCT combined with statistical iterative reconstruction (SIR) for low-dose imaging of patients with spinal instrumentation. MATERIALS AND METHODS. Thirty-eight patients with implanted hardware after spinal instrumentation (24 patients with short- or long-term instrumentation-related complications [i.e., adjacent segment disease, screw loosening or implant failure, or postoperative hematoma or seroma] and 14 control subj...     »
Zeitschriftentitel:
AJR Am J Roentgenol
Jahr:
2021
Band / Volume:
216
Heft / Issue:
5
Seitenangaben Beitrag:
1308-1317
Volltext / DOI:
doi:10.2214/AJR.20.23083
PubMed:
http://view.ncbi.nlm.nih.gov/pubmed/33703925
Print-ISSN:
0361-803X
TUM Einrichtung:
Fachgebiet Neuroradiologie (Prof. Zimmer); Institut für Diagnostische und Interventionelle Radiologie; Neurochirurgische Klinik und Poliklinik