Abstract:
BACKGROUND: Intraoperative neuromonitoring can help to navigate anesthesia. Pronounced alpha oscillations in the frontal electroencephalogram (EEG) appear to predict favorable perioperative neurocognitive outcomes and may also provide a measure of intraoperative antinociception. Monitoring the presence and strength of these alpha oscillations can be challenging, especially in elderly patients, because the EEG in these patients may be dominated by oscillations in other frequencies. Hence, the inf...     »