Benutzer: Gast  Login
Mehr Felder
Einfache Suche
Titel:

Comparison of a novel Compressed SENSE accelerated 3D modified relaxation-enhanced angiography without contrast and triggering with CE-MRA in imaging of the thoracic aorta.

Dokumenttyp:
Article; Journal Article
Autor(en):
Pennig, Lenhard; Wagner, Anton; Weiss, Kilian; Lennartz, Simon; Huntgeburth, Michael; Hickethier, Tilman; Maintz, David; Naehle, Claas Philip; Bunck, Alexander Christian; Doerner, Jonas
Abstract:
To compare a novel Compressed SENSE accelerated ECG- and respiratory-triggered flow-independent 3D isotropic Relaxation-Enhanced Angiography without Contrast and Triggering (modified REACT) with standard non-ECG-triggered 3D contrast-enhanced magnetic resonance angiography (CE-MRA) for imaging of the thoracic aorta in patients with connective tissue diseases (CTD) or other aortic diseases using manual and semiautomatic measurement approaches. This retrospective, single-center analysis of 30 patients (June-December 2018) was conducted by two radiologists, who independently measured aortic diameters on modified REACT and CE-MRA using manual (Multiplanar-Reconstruction) and semiautomatic (Advanced Vessel Analysis) measurement tools on seven levels (inner edge): Aortic annulus and sinus, sinotubular junction, mid- and high-ascending aorta, aortic isthmus, and descending aorta. Bland-Altman analysis was conducted to evaluate differences between the mean values of aortic width and ICCs were calculated to assess interobserver agreement. For each level, image quality was evaluated on a four-point scale in consensus with Wilcoxon matched-pair test used to evaluate for differences between both MRA techniques. Additionally, evaluation time for each measurement technique was noted, which was compared applying one-way ANOVA. When comparing both imaging and measurement methods, CE-MRA (mean difference 0.24 ± 0.27 mm) and the AVA-tool (- 0.21 ± 0.15 mm) yielded higher differences compared to modified REACT (- 0.11 ± 0.11 mm) and the MPR-tool (0.07 ± 0.21 mm) for all measurement levels combined without yielding clinical significance. There was an excellent interobserver agreement between modified REACT and CE-MRA using both tools of measurement (ICC > 0.9). Modified REACT (average acquisition time 06:34 ± 01:36 min) provided better image quality from aortic annulus to mid-ascending aorta (p < 0.05), whereas at distal measurement levels, no significant differences were noted. Regarding time requirement, no statistical significance was found between both measurement techniques (p = 0.08). As a novel non-CE-MRA technique, modified REACT allows for fast imaging of the thoracic aorta with higher image quality in the proximal aorta than CE-MRA enabling a reliable measurement of vessel dimensions without the need for contrast agent. Thus, it represents a clinically suitable alternative for patients requiring repetitive imaging. Manual and semiautomatic measurement approaches provided comparable results without significant difference in time need.
Zeitschriftentitel:
Int J Cardiovasc Imaging
Jahr:
2021
Band / Volume:
37
Heft / Issue:
1
Seitenangaben Beitrag:
315-329
Volltext / DOI:
doi:10.1007/s10554-020-01979-2
PubMed:
http://view.ncbi.nlm.nih.gov/pubmed/32852711
Print-ISSN:
1569-5794
TUM Einrichtung:
1038; Klinik für Kinderkardiologie und angeborene Herzfehler (Prof. Hess)
 BibTeX