User: Guest  Login
Title:

Tube Current Reduction in CT Angiography: How Low Can We Go in Imaging of Patients With Suspected Acute Stroke?

Document type:
Journal Article
Author(s):
Sollmann, Nico; Mei, Kai; Riederer, Isabelle; Schön, Simon; Kopp, Felix K; Löffler, Maximilian T; Hedderich, Dennis M; Maegerlein, Christian; Friedrich, Benjamin; Kreiser, Kornelia; Boeckh-Behrens, Tobias; Kirschke, Jan S; Rummeny, Ernst J; Zimmer, Claus; Noël, Peter B; Baum, Thomas
Abstract:
OBJECTIVE. The purpose of this study was to systematically evaluate image quality, detectability of large-vessel occlusion or dissection, and diagnostic confidence in CT angiography (CTA) with virtually lowered tube current and iterative reconstruction in patients with suspected acute stroke. MATERIALS AND METHODS. Thirty patients (15 with large-vessel occlusion or dissection) underwent CTA of the supraaortal up to the intracranial arterial vessels. CTA scans were simulated as if they were made...     »
Journal title abbreviation:
AJR Am J Roentgenol
Year:
2019
Journal volume:
213
Journal issue:
2
Pages contribution:
410-416
Fulltext / DOI:
doi:10.2214/AJR.18.20954
Pubmed ID:
http://view.ncbi.nlm.nih.gov/pubmed/31039015
Print-ISSN:
0361-803X
TUM Institution:
Fachgebiet Neuroradiologie (Prof. Zimmer)