User: Guest  Login
More Searchfields
Simple search
Document type:
Journal Article
Author(s):
Werner, P; Neumann, C; Eiber, M; Wester, H J; Schottelius, M
Title:
[99cmTc]Tc-PSMA-I&S-SPECT/CT: experience in prostate cancer imaging in an outpatient center.
Abstract:
BACKGROUND: Prostate-specific membrane antigen (PSMA) SPECT imaging in prostate cancer (PCa) could be a valuable alternative in regions where access to PSMA-PET imaging is restricted. [99mTc]Tc-PSMA-I&S is a new 99mTc-labeled PSMA-targeting SPECT agent, initially developed for radio-guided surgery. We report on the diagnostic use of [99mTc]Tc-PSMA-I&S-SPECT/CT in PCa. RESULTS: [99mTc]Tc-PSMA-I&S-SPECT/CT was performed and evaluated in 210 outpatients with PCa at a single center. Patients were imaged for biochemical recurrence (BCR, n = 152, mean PSA 8.7 ng/ml), for primary staging of high-risk PCa (n = 12, mean PSA 393 ng/ml), and restaging in advanced recurrent PCa (n = 46, mean PSA 101.3 ng/ml). Number and location of positive lesions were determined for the different subgroups. For BCR, detection rates were calculated, defined as the proportion of scans with at least one PSMA-positive lesion. PSMA positive lesions were detected in 65.2% of all 210 patients. Tumor tissue was mainly detected in lymph nodes (59%), in the bone (42%), and in the prostate (fossa) (28%). In the subgroup of patients referred for detection of BCR the detection rate increased from 20% at a PSA level < 1 ng/ml to 82.9% and 100% at PSA levels > 4 ng/ml and > 10 ng/ml, respectively. In the subgroup of high-risk patients referred for primary staging, 42% demonstrated metastatic disease. Restaging of advanced recurrent PCa revealed detectability of PSMA positive tumor lesions in 85% of the scans. CONCLUSIONS: [99mTc]Tc-PSMA-I&S-SPECT/CT was useful in PSMA-targeted imaging of PCa at various clinical stages. At low PSA levels (< 4 ng/ml), detection rates of [99mTc]Tc-PSMA-I&S-SPECT/CT in BCR are clearly inferior to data reported for PET-imaging and should thus only be considered for lesion detection if imaging with PET is unavailable. However, at higher PSA levels (> 4 ng/ml) [99mTc]Tc-PSMA-I&S-SPECT/CT provides high detection rates in BCR. [99mTc]Tc-PSMA-I&S-SPECT/CT can also be used for primary staging and for restaging of advanced recurrent PCa. However, further studies are needed to assess the clinical value in these indications.
Journal title abbreviation:
EJNMMI Res
Year:
2020
Journal volume:
10
Journal issue:
1
Fulltext / DOI:
doi:10.1186/s13550-020-00635-z
Pubmed ID:
http://view.ncbi.nlm.nih.gov/pubmed/32382945
Print-ISSN:
2191-219X
TUM Institution:
Klinik und Poliklinik für Nuklearmedizin
 BibTeX