Benutzer: Gast  Login
Mehr Felder
Einfache Suche
Titel:

A method for material parameter determination for the human mandible based on simulation and experiment.

Dokumenttyp:
Evaluation Studies; Journal Article; Validation Studies
Autor(en):
Clason, C; Hinz, AM; Schieferstein, H
Abstract:
In cranio-maxillofacial surgery planning and implant design, it is important to know the elastic response of the mandible to load forces as they occur, e.g., in biting. The goal of the present study is to provide a method for a quantitative determination of material parameters for the human jaw bone, whose values can, e.g., be used to devise a prototype plastic model for the mandible. Non-destructive load experiments are performed on a cadaveric mandible using a specially designed test bed. The...     »
Zeitschriftentitel:
Comput Methods Biomech Biomed Engin
Jahr:
2004
Band / Volume:
7
Heft / Issue:
5
Seitenangaben Beitrag:
265-76
Sprache:
eng
Volltext / DOI:
doi:10.1080/10255840412331313590
PubMed:
http://view.ncbi.nlm.nih.gov/pubmed/15621649
Print-ISSN:
1025-5842
TUM Einrichtung:
Klinik und Poliklinik für Orthopädie und Sportorthopädie
 BibTeX