User: Guest  Login
Less Searchfields
Simple search
Document type:
Case Reports
Author(s):
Pesch, Sebastian; Gromer, Alexander; Beirer, Marc; Huber-Wagner, Stefan; Biberthaler, Peter; Kirchhoff, Chlodwig M
Title:
Augmentation of simultaneous acetabular and femoral neck fracture in osteogenesis imperfecta using photodynamic bone stabilization - A case report.
Abstract:
Background: Surgical fracture treatment in patients suffering from "osteogenesis imperfecta" (OI) is challenging and often results in unsatisfactory fixation of implants due to altered bone quality. Even the use of locking plates bears a residual risk to develop a loss of reduction leading to secondary fracture dislocation. However, the augmentation with an intramedullary photodynamic bone stabilization system (PBS) (e.g. Illuminoss®) may increase bone stability and allow for a sufficient anchor...     »
Journal title abbreviation:
Trauma Case Rep
Year:
2019
Journal volume:
24
Fulltext / DOI:
doi:10.1016/j.tcr.2019.100200
Pubmed ID:
http://view.ncbi.nlm.nih.gov/pubmed/31872019
TUM Institution:
Klinik und Poliklinik für Unfallchirurgie
 BibTeX