Benutzer: Gast  Login
Mehr Felder
Einfache Suche
Titel:

Thirty-day clinical outcomes of the Evolut PRO self-expanding transcatheter aortic valve: the international FORWARD PRO study.

Dokumenttyp:
Journal Article
Autor(en):
Manoharan, Ganesh; Grube, Eberhard; Van Mieghem, Nicolas M; Brecker, Stephen; Fiorina, Claudia; Kornowski, Ran; Danenberg, Haim; Ruge, Hendrik; Thiele, Holger; Lancellotti, Patrizio; Søndergaard, Lars; Tamburino, Corrado; Oh, Jae K; Fan, Yunhua; Windecker, Stephan
Abstract:
AIMS: The Evolut PRO is a new transcatheter heart valve with an outer pericardial wrap intended to reduce paravalvular leak and facilitate tissue ingrowth. We aimed to evaluate the clinical performance and safety of the Evolut PRO valve in standard practice. METHODS AND RESULTS: FORWARD PRO is a prospective, multinational, multicentre observational study. Transcatheter aortic valve implantation with the Evolut PRO valve (23, 26, or 29 mm) was attempted in 629 non-consecutive patients from 39 cen...     »
Zeitschriftentitel:
EuroIntervention
Jahr:
2020
Band / Volume:
16
Heft / Issue:
10
Seitenangaben Beitrag:
850-857
Volltext / DOI:
doi:10.4244/EIJ-D-20-00279
PubMed:
http://view.ncbi.nlm.nih.gov/pubmed/32748789
Print-ISSN:
1774-024X
TUM Einrichtung:
Klinik für Herz- und Gefäßchirurgie (Prof. Lange)