Prenatal diagnosis of tetralogy of Fallot with pulmonary atresia (TOF/PA) was confirmed in a newborn with a birth weight of 2,095 g. Additionally, an aortopulmonary window (APW) type I was diagnosed on echocardiography. The operation was performed at the age of 4 weeks due to congestive heart failure. The APW was closed with a pericardial patch, the ventricular septal defect (VSD) with a Dacron patch, and the right ventricular outflow tract (RVOT) was reconstructed with a 12-mm bovine jugular vein valved conduit (Contegra, Medtronic Inc., Minneapolis, MN, USA). At 15-month follow-up, the patient is in excellent clinical condition without medication. On echocardiography, the conduit showed a mean gradient of 11 mmHg with first-degree insufficiency.
«
Prenatal diagnosis of tetralogy of Fallot with pulmonary atresia (TOF/PA) was confirmed in a newborn with a birth weight of 2,095 g. Additionally, an aortopulmonary window (APW) type I was diagnosed on echocardiography. The operation was performed at the age of 4 weeks due to congestive heart failure. The APW was closed with a pericardial patch, the ventricular septal defect (VSD) with a Dacron patch, and the right ventricular outflow tract (RVOT) was reconstructed with a 12-mm bovine jugular ve...
»