Lill, H; Hepp, P; Rose, T; König, K; Josten, C
Abstract:
The Locking-Proximal-Humerus-Plate (LPHP) was slided from proximally to distally through a small anterior-lateral-deltoid-splitting-approach following a closed reduction. Additional tension band wiring for the rotator cuff was fixed at the plate after screw insertion. The prospective study included 35 patients (age median: 63 years, range: 33-92; male: 13, female: 22) from 08/01-05/02. The follow-up period was set to 3 months postoperatively, whereas 29 patients were able to attend. The patient...     »
Journal title abbreviation:
Zentralbl Chir
Year:
2004
Journal volume:
129
Journal issue:
1
Pages contribution:
43-8