Purpose: The implementation of intensity-modulated radiotherapy (IMRT) technique into clinical practice is becoming routine, but still lacks a generally accepted method for plan evaluation. We present a comparison of the dose distribution of conformal three-dimensional radiotherapy plans with IMRT plans for cranial lesions in stereotactic radiotherapy. The primary aim of this study was to judge the quality of the treatment plans. The next purpose was to assess the usefulness of several quality factors for plan evaluation. Methods and Materials: Five patients, who were treated in our department, were analyzed. Four had meningioma and one had pituitary adenoma. For each case, 10 different plans were created and analyzed: 2 conventional conformal three-dimensional plans and 8 IMRT plans, using the "step and shoot" delivery method. The first conventional plan was an individually designed beam arrangement and was used for patient treatment. The second plan was a standard plan with the same beam arrangement for all patients. Beam arrangements from the conformal plans were the base for the inversely planned IMRT. To evaluate the plans, the following factors were investigated: minimal and maximal dose to the planning target volume, homogeneity index, coverage index, conformity index, and tumor control probabilities and normal tissue complication probabilities. These quantities were incorporated into scoring factors and assigned to each plan. Results: The greatest homogeneity was reached in the conformal plans and IMRT plans with high planning target volume priority in the optimization process. This consequently led to a better probability of tumor control. Better protection of organs at risk and thereby lower normal tissue complication probabilities were achieved in the IMRT plans with increased weighting of the organs at risk. Conclusion: These results show the efficiency, as well as some limitations, of the IMRT techniques. The use of different quality factors allowed us to assess the dose distribution in more depth.
«
Purpose: The implementation of intensity-modulated radiotherapy (IMRT) technique into clinical practice is becoming routine, but still lacks a generally accepted method for plan evaluation. We present a comparison of the dose distribution of conformal three-dimensional radiotherapy plans with IMRT plans for cranial lesions in stereotactic radiotherapy. The primary aim of this study was to judge the quality of the treatment plans. The next purpose was to assess the usefulness of several quality f...
»