Multiple operations have been proposed to slow the progression of osteonecrosis and secondary carpal damage in Kienböck's disease. To assess the biomechanical changes after capitate shorting, we inserted pressure-testing devices into the carpal and radiocarpal joints in an anatomical study. Pressure sensors were placed into eight thawed non-fixated human cadaver arms to measure the forces transmitted in physiological loading. Longitudinal 9.8 N and 19.6 N forces were applied before and after capitate shortening. After capitate shortening, significant load reduction on the lunate was evident in all specimens. An average decrease of 49% was seen under a 9.8 N load and 56% under a 19.6 N load. The load was transferred to the radial and ulnar intercarpal joints. More relief of pressure on the lunate after isolated capitate shortening is achieved with a shallow angle between the scaphoid and capitate in the posteroanterior radiograph.
«
Multiple operations have been proposed to slow the progression of osteonecrosis and secondary carpal damage in Kienböck's disease. To assess the biomechanical changes after capitate shorting, we inserted pressure-testing devices into the carpal and radiocarpal joints in an anatomical study. Pressure sensors were placed into eight thawed non-fixated human cadaver arms to measure the forces transmitted in physiological loading. Longitudinal 9.8 N and 19.6 N forces were applied before and after cap...
»