Benutzer: Gast  Login
Dokumenttyp:
Comparative Study; Journal Article; Multicenter Study; Randomized Controlled Trial
Autor(en):
Hanschen, Marc; Aschenbrenner, Ina M; Fehske, Kai; Kirchhoff, Sonja; Keil, Leonhard; Holzapfel, Boris M; Winkler, Sebastian; Fuechtmeier, Bernd; Neugebauer, Rainer; Luehrs, Sven; Liener, Ulrich; Biberthaler, Peter
Titel:
Mono- versus polyaxial locking plates in distal femur fractures: a prospective randomized multicentre clinical trial.
Abstract:
Treatment of complex fractures of the distal femur utilizing monoaxial locking plates (e.g. Less Invasive Stabilisation System, LISS®, Synthes) is considered to be superior to conventional plating systems. Due to the limitation that the thread forces the screw into pre-determined positions, modifications have been made to allow screw positioning within a range of 30° (Non Contact Bridging, NCB®-DF, Zimmer). For the first time, this multicenter prospective randomized clinical trial (RCT) investig...     »
Zeitschriftentitel:
Int Orthop
Jahr:
2014
Band / Volume:
38
Heft / Issue:
4
Seitenangaben Beitrag:
857-63
Volltext / DOI:
doi:10.1007/s00264-013-2210-0
PubMed:
http://view.ncbi.nlm.nih.gov/pubmed/24326361
Print-ISSN:
0341-2695
TUM Einrichtung:
Klinik und Poliklinik für Unfallchirurgie
 BibTeX