User: Guest  Login
Title:

A diameter matched comparison of wall stress and rupture potential index for abdominal aortic aneurysm

Document type:
Konferenzbeitrag
Contribution type:
Textbeitrag / Aufsatz
Author(s):
Gee, M.W.; Maier, A.; Reeps, C.; Eckstein, H.-H.; Wall, W.A.
Pages contribution:
CD-ROM SBC2010-19015
Abstract:
Increased blood pressure and arterial wall degradation lead to formation of abdominal aortic aneurysms (AAA). As elective AAA surgery is not without potential risk it is common practice to balance risk of rupture against risk of intervention. Usually a max. AAA diameter is the clinically accepted parameter where diameter > 55mm indicates intervention. However, it has been shown that computational wall stress analyses is a better indicator for rupture risk, e.g. by Fillinger et al 2003. In the pr...     »
Dewey Decimal Classification:
620 Ingenieurwissenschaften
Book / Congress title:
Proceedings ASME 2010 Summer Bioengineering Conference
Congress (additional information):
SBC 2010
Organization:
ASME
Year:
2010
Reviewed:
ja
Language:
en
Publication format:
CD-ROM / DVD
Semester:
WS 10-11
Format:
Text