Benutzer: Gast  Login
Titel:

[Sutureless encircling band - clinical experience].

Dokumenttyp:
English Abstract; Journal Article; Article
Autor(en):
Maier, MM; Feucht, N; Winkler von Mohrenfels, C; Kotliar, K; Fabian, E; Lohmann, CP
Abstract:
In cases with multiple retinal breaks and in combination with vitrectomy in eyes with proliferative vitreoretinopathy (PVR) often an encircling band is used for retinal detachment surgery. Usually the encircling band is fixed with non-resorbable sutures.A fixation method for an encircling band in retinal detachment surgery with one scleral tunnel in each of the 4 quadrants is reported. After 50 consecutive operations on 50 patients, we describe our experience and biomechanical calculations of th...     »