Benutzer: Gast  Login
Dokumenttyp:
Konferenzbeitrag
Autor(en):
Braun, S.; Frech, A.; Slim, H. H.; Russer, P.
Titel:
Automation of radiated emission measurements with an ultra-fast time-domain EMI measurement system
Abstract:
Traditionally emission measurements are performed in frequency domain and take a long time for a single scan. Pre- and final scans are performed to reduce the time for the characterization of the device under test. Emission measurements in time-domain can reduce the measurement time for a single scan up to a factor of 4000. In this paper novel test procedures for automated radiated emission measurements are presented. Based on an initial scan the minimum dwell time required by the instationarity...     »
Stichworte:
electromagnetic interference, time-domain analysis, frequency 30 MHz to 1 GHz, anechoic chamber, anechoic chambers (electromagnetic), field emission, field strength measurement, radiated emission measurements, ultrafast time-domain EMI measurement system
Kongress- / Buchtitel:
Electromagnetic Compatibility and 19th International Zurich Symposium on Electromagnetic Compatibility, 2008. APEMC 2008. Asia-Pacific Symposium on
Jahr:
2008
Seiten:
303--306
Volltext / DOI:
doi:10.1109/VETECS.2008.61