Benutzer: Gast  Login
Titel:

Digital automatic calibration method for a time-interleaved ADCs system used in time-domain EMI measurement receiver

Dokumenttyp:
Konferenzbeitrag
Autor(en):
Slim, H. H; Russer, P.
Abstract:
The sampling rate of state of the art analog to digital converters (ADCs) limits the base-band frequency range of real-time time domain electromagnetic interference (TD-EMI) measurement systems to 1 GHz. In this paper, a time interleaved sampling architecture is introduced to overcome this limitation and to extend the baseband of the time-domain EMI receiver. Using three parallel time-interleaved ADC converters a TD-EMI measurement system with 3 GHz base bandwidth has been realized. The misalign...     »
Stichworte:
electromagnetic interference, time domain analysis, Frequency measurement, receivers, analog to digital converters, analogue-digital conversion, automatic calibration routine, bandwidth 3 GHz, calibration, CISPR standards, clocks, digital automatic calibration, real-time electromagnetic interference, Registers, sampling rate, time interleaved sampling architecture, time-domain EMI measurement receiver, time-interleaved ADC system
Kongress- / Buchtitel:
2011 IEEE International Symposium on Electromagnetic Compatibility (EMC)
Verlag / Institution:
IEEE
Jahr:
2011
Monat:
August
Seiten:
476--479
Print-ISBN:
978-1-4577-0812-1
Volltext / DOI:
doi:10.1109/ISEMC.2011.6038358
 BibTeX