Benutzer: Gast  Login
Dokumenttyp:
Konferenzbeitrag
Autor(en):
Slim, H. H; Russer, P.
Titel:
A prototype for a time-domain EMI measurement system using pipelined time-interleaved ADCs up to 4 GHz
Abstract:
The limited frequency range covered by state of the art analog to digital converter (ADC) technology requires the application of RF down converting methods to extend the frequency range of real-time time-domain EMI measurement systems beyond 1 GHz. In this paper the concept of Time Interleaved Sampling is introduced to extend the frequency range of time domain EMI measurement systems. It is shown that the application of time interleaved sampling with three ADCs can increase the baseband range of...     »
Stichworte:
Antenna measurements, electromagnetic interference, time domain analysis, analogue-digital conversion, clocks, analog to digital converter, Channel Mismatch, CISPR standard requirements, Detectors, electric variables measurement, emission measurement system, harmonic test signal, magnetic variables measurement, pipelined time-interleaved ADC, real-time time-domain EMI measurement systems, RF down converting method, Spurious Free Dynamic Range (SFDR), time frequency analysis, Time Interleaved Ana...     »
Kongress- / Buchtitel:
Microwave Conference (GeMIC), 2011 German
Verlag / Institution:
IEEE
Jahr:
2011
Monat:
March
Seiten:
1--4
Print-ISBN:
978-1-4244-9225-1
 BibTeX