User: Guest  Login
Original title:
3D mesoscopic scale optoacoustic imaging using linear array transducers 
Translated title:
Mesoskopische optoakustische 3D Bildgebung mit linearen Ultraschallsonden 
Year:
2017 
Document type:
Dissertation 
Institution:
Fakultät für Elektrotechnik und Informationstechnik 
Advisor:
Ntziachristos, Vasilis (Prof. Dr.) 
Referee:
Ntziachristos, Vasilis (Prof. Dr.); Menze, Bjoern (Prof. Dr.) 
Language:
en 
Subject group:
BIO Biowissenschaften; ELT Elektrotechnik; MED Medizin 
Abstract:
Traditional mesoscopic scale imaging methods (Histology, Selective Plane Illumination Microscopy and Optical Projection Tomography) require destructive or chemical clearing procedures of the sample. Optoacoustic imaging provides non-invasive high-resolution mapping of optical absorption up to a few centimeters depth into tissue. In this work, three different volumetric detection geometries using linear array transducers are introduced in order to provide new anatomical, molecular, and functional...    »
 
Translated abstract:
Bestehende mesoskopische Bildgebungsmethoden (Histologie, Lichtblattmikroskopie und optische Projektionstomographie) kommen nicht ohne physische Zerstörung oder chemische Vorbehandlung der Probe aus. Die optoakustische Bildgebung kann optische Absorption Zentimeter tief im Gewebe darstellen. In dieser Arbeit werden drei volumetrische Detektionsgeometrien basierend auf handelsüblichen Ultraschalldetektoren vorgestellt, um neue anatomische, molekulare und funktionale Erkenntnisse über mesoskopisch...    »
 
Oral examination:
09.02.2017 
File size:
62981676 bytes 
Pages:
175 
Last change: