Kessler, Sylvia; Gehlen, Christoph
Titel:
Reliability Evaluation of Half-Cell Potential Measurement Using POD
Abstract:
The detection of corrosion in reinforced concrete structures is one of the primary tasks during inspection. The most common inspection method used is the half-cell potential method. From half-cell potential readings, a judgment is made by allocating investigated structural concrete surfaces to either corrosion detected or corrosion not detected. In this paper, the development of so-called probability of (corrosion) detection (POD) curves is presented. A numerical approach is presented for eva...     »