Abstract:
The detection of corrosion in reinforced concrete structures is one of the primary tasks during inspection. The most common inspection method used is the half-cell potential method. From half-cell potential readings, a judgment is made by allocating investigated structural concrete surfaces to either corrosion detected or corrosion not detected. In this paper, the development of so-called probability of (corrosion) detection (POD) curves is presented. A numerical approach is presented for...    »
 
Zeitschriftentitel:
Journal of Infrastructure Systems 
Jahr:
2017 
Band / Volume:
23 
Heft / Issue:
Seitenangaben Beitrag:
B4016007 
Sprache:
en 
Verlag / Institution:
American Society of Civil Engineers (ASCE) 
E-ISSN:
1076-03421943-555X 
Publikationsdatum:
01.06.2017