A Time-Domain System for the Measurement of Non-Stationary EMI up to 40 GHz 
Abstract:
In this paper, a time-domain measurement system for EMI measurements according to CISPR 16-1-1, MIL-461 and DO-160 in the frequency range from 10 Hz-40 GHz is presented. Signals with a frequency of up to 1.1 GHz are sampled by an ultra-fast floating-point analog-to-digital-converter (ADC), whereas signals from 1.1-40 GHz are first down-converted by an ultra-broadband multi-stage down-converter. With integrated preamplifiers, the system offers high sensitivity and maintains a low system noise flo...    »
 
Book / Congress title:
Proc. Asia-Pacific Symposium on Electromagnetic Compatibility APEMC 
Congress (additional information):
Singapore, May 21 - 24, 2012 
Congress city:
Singapore, Singapore 
Publisher:
IEEE Xplore Digital Library 
Year:
2012 
Quarter:
2. Quartal 
Year / month:
2012-05 
Month:
May 
Pages:
205 - 208 