User: Guest  Login
Document type:
journal article 
Author(s):
Treier, R; Steingoetter, A; Goetze, O; Fox, M; Fried, M; Schwizer, W; Boesiger, P 
Title:
Fast and optimized T1 mapping technique for the noninvasive quantification of gastric secretion. 
Abstract:
PURPOSE: To evaluate the noninvasive quantification of gastric secretion volume after administration of a labeled viscous glucose solution by fast T(1) mapping. MATERIALS AND METHODS: T(1) values of a series of labeled and diluted glucose solutions were measured in vitro to characterize the interrelationship between T(1) and contrast agent concentration (C(Gd)) as well as the dependency of relaxivity and reference T(1) (T(10)) on the macromolecular concentration. Abdominal T(1) mapping in five h...    »
 
Journal title abbreviation:
J Magn Reson Imaging 
Year:
2008 
Journal volume:
28 
Journal issue:
Pages contribution:
96-102 
Language:
eng 
Print-ISSN:
1053-1807 
TUM Institution:
Nuklearmedizinische Klinik und Poliklinik