User: Guest  Login
Original title:
Development of low-field and mobile MRI devices and methods to monitor xylem emboli in trees 
Translated title:
Entwicklung von Niederfeld- und mobilen MRT-Methoden und Geräten zum Beobachten von Xylemembolien in Bäumen 
Year:
2021 
Document type:
Dissertation 
Institution:
TUM School of Life Sciences 
Advisor:
Först, Petra (Prof. Dr. habil.) 
Referee:
Först, Petra (Prof. Dr. habil.); Rammig, Anja (Prof. Dr.) 
Language:
en 
Subject group:
NAT Naturwissenschaften (allgemein) 
TUM classification:
LEB 054 
Abstract:
Small, low-field magnetic resonance imaging devices and methods are developed and evaluated, which aim to image xylem water content changes in trees in vivo, and to monitor and quantify xylem embolism formation due to drought stress in particular. Dedicated combinations of purpose-built imaging hardware and software are introduced and verified in dry-down experiments on young beech and spruce trees. Novel approaches to process magnetic resonance images for obtaining xylem vulnerability curves ar...    »
 
Translated abstract:
Es werden kompakte Magnetresonanztomographie-Geräte mit begrenzter Feldstärke und Methoden entwickelt und evaluiert, mit dem Ziel Änderungen im Xylemwassergehalt von Bäumen zu visualisieren und zu quantifizieren. Speziell werden durch Trockenstress hervorgerufene Xylemembolien in vivo beobachtet und quantifiziert. Eine Kombination von Hardware und Bildgebungssoftware wird entwickelt und in Austrocknungsexperimenten an jungen Buchen und Fichten getestet. Neue MR-Bildprozessierungsansätze für das...    »
 
Oral examination:
05.10.2021 
File size:
16514664 bytes 
Pages:
95 
Last change:
19.11.2021