User: Guest  Login
Document type:
Journal Article; Article
Author(s):
Jahn, T; Steffens, KJ
Title:
Press chamber coating as external lubrication for high speed rotary presses: lubricant spray rate optimization.
Abstract:
Lubrication of the tooling (punches and dies) is necessary to produce tablets. The most commonly used lubricant is magnesium stearate. Adding and blending magnesium stearate to the tablet mass often has negative effects on the properties of the compressed tablets (e.g., decreasing the tensile strength of the tablet). To avoid these negative effects, external lubrication systems were developed. This study investigated the functionality and the influence of a new press chamber coating system calle...     »
Journal title abbreviation:
Drug Dev Ind Pharm
Year:
2005
Journal volume:
31
Journal issue:
10
Pages contribution:
951-7
Language:
eng
Fulltext / DOI:
doi:10.1080/03639040500306161
Pubmed ID:
http://view.ncbi.nlm.nih.gov/pubmed/16316850
Print-ISSN:
0363-9045
TUM Institution:
Klinik und Poliklinik für Psychiatrie und Psychotherapie
 BibTeX