User: Guest  Login
Document type:
Case Reports; English Abstract; Journal Article
Author(s):
Maier, MM; Engelmann, V; Pfrommer, S; Perz, C; Löhmann, C
Title:
[Early emulsification of silicone oil (2000 cs) in minimally invasive transconjunctival vitreoretinal surgery].
Abstract:
The highly purified polydimethylsiloxane (PDMS) with a viscosity of 5000 centistokes (cs) is the preferred silicone oil endotamponade in vitreoretinal surgery (20 gauge) and shows high stability. In contrast in transconjunctival minimally invasive surgery (23 gauge) the application of 5000 cs. silicone oil shows substantial disadvantages because of time-consuming and difficult application procedure due to the small lumen of the used surgical equipment. Consequently silicone oils with lower visco...     »
Journal title abbreviation:
Klin Monatsbl Augenheilkd
Year:
2011
Journal volume:
228
Journal issue:
5
Pages contribution:
477-9
Language:
de
Fulltext / DOI:
doi:10.1055/s-0029-1245362