User: Guest  Login
Document type:
Zeitschriftenaufsatz 
Author(s):
Kessler, Sylvia; Gehlen, Christoph 
Title:
Reliability Evaluation of Half-Cell Potential Measurement Using POD 
Abstract:
The detection of corrosion in reinforced concrete structures is one of the primary tasks during inspection. The most common inspection method used is the half-cell potential method. From half-cell potential readings, a judgment is made by allocating investigated structural concrete surfaces to either corrosion detected or corrosion not detected. In this paper, the development of so-called probability of (corrosion) detection (POD) curves is presented. A numerical approach is presented for...    »
 
Journal title:
Journal of Infrastructure Systems 
Year:
2017 
Journal volume:
23 
Journal issue:
Pages contribution:
B4016007 
Language:
en 
Publisher:
American Society of Civil Engineers (ASCE) 
E-ISSN:
1076-03421943-555X 
Date of publication:
01.06.2017