User: Guest  Login
Author(s):
Hoffmann, Christian; Russer, Peter
Title:
A Time-Domain System for EMI Measurements Above 1 GHz with High Sensitivity
Pages contribution:
1--4
Abstract:
In this work, a broadband Time-Domain EMI Measurement System with high sensitivity for measurements from 9 kHz to 18 GHz is presented. Combining ultra-fast analog-to-digital-conversion and real-time digital signal processing on a field-programmable-gate-array (FPGA) with ultra-broadband multi-stage down-conversion, scan times can be reduced by several orders of magnitude in comparison to a traditional heterodyne EMI Receiver. The system's ultra-low noise figure of 6-8 dB over the complete freque...     »
Keywords:
analogue-digital conversion, Antenna measurements, broadband communication, broadband measurement, electromagnetic interference, EMI receiver, field programmable gate array, field programmable gate arrays, frequency 9 kHz to 18 GHz, Frequency measurement, microwave measurement, Microwave measurements, noise, real-time spectrogram, time domain analysis, time-domain EMI measurement system, ultra-fast analog-to-digital-conversion
Book / Congress title:
German Microwave Conference (GeMIC)
Publisher:
IEEE
Publisher address:
Darmstadt, Germany
Year:
2011
Month:
mar