Awake craniotomies represent an essential opportunity in the case of lesions in eloquent areas. Thus, optimal surveillance of the patient during different stages of sedation, as well as the detection of seizure activity during brain surgery, remains difficult, as skin electrodes for electroencephalographic (EEG) analysis are not applicable in most cases. We assessed the applicability of ECoG to monitor different stages of sedation, as well as the influence of different patient characteristics, s...     »