User: Guest  Login
Original title:
Fire resistance of hot-dip galvanized steel structures 
Translated title:
Feuerwiderstand feuerverzinkter Stahlkonstruktionen 
Year:
2019 
Document type:
Dissertation 
Institution:
Ingenieurfakultät Bau Geo Umwelt 
Advisor:
Mensinger, Martin (Prof. Dr.) 
Referee:
Mensinger, Martin (Prof. Dr.); Knobloch, Markus (Prof. Dr.); Wald, Frantisek (Prof. Dr.) 
Language:
en 
Subject group:
BAU Bauingenieurwesen, Vermessungswesen; WER Werkstoffwissenschaften 
Keywords:
emissivity, fire design, fire resistance, hot-dip galvanizing, R30 unprotected, steel structures 
Translated keywords:
Brandschutz, Emissivität, Feuerverzinkung, R30 ungeschützt, Stahlkonstruktionen 
TUM classification:
BAU 500d; BAU 340d 
Abstract:
Once a fire resistance rating is necessary, it has to be proven that the load bearing behaviour of a steel construction in the accidental situation of fire still fits the static demands. For this purpose, positive effects of hot-dip galvanized steel members on the temperature development in case of fire has been investigated in this dissertation. The results show a significant better heating behaviour of hot-dip galvanized steel components, due to a lower emissivity. This temperature-dependent p...    »
 
Translated abstract:
Sobald eine Feuerwiderstandsdauer erforderlich ist, muss nachgewiesen werden, dass das Tragverhalten der Stahlkonstruktion unter Brandeinwirkung weiterhin den statischen Anforderungen genügt. Zu diesem Zweck wurden in dieser Dissertation positive Effekte der Feuerverzinkung auf die Stahltemperaturentwicklung in der außergewöhnlichen Lastsituation eines Brandes untersucht. Die Ergebnisse zeigen ein deutlich besseres Erwärmungsverhalten von feuerverzinkten Stahlbauteilen aufgrund eines niedrigeren...    »
 
Oral examination:
06.12.2019 
File size:
11456597 bytes 
Pages:
211 
Last change:
13.01.2020