User: Guest  Login
Original title:
Study of Muon Drift Tube Detectors and Fast Readout Electronics for Very High Counting Rates 
Translated title:
Studie von Myondriftrohdetektoren und schneller Ausleseelektronik für sehr hohe Zählraten 
Year:
2020 
Document type:
Dissertation 
Institution:
Fakultät für Physik 
Advisor:
Kroha, Hubert (Prof. Dr.) 
Referee:
Kroha, Hubert (Prof. Dr.); Oberauer, Lothar (Prof. Dr.) 
Language:
en 
Subject group:
PHY Physik 
TUM classification:
PHY 000d 
Abstract:
After the luminosity upgrade of the Large Hadron Collider (HL-LHC), the rate capability of the muon drift tube detectors of the ATLAS experiment will be exceeded due to the higher particle background rates. Therefore, new small-diameter Muon Drift Tube (sMDT) chambers have been developed. The performance of the sMDT chambers has been studied up to even higher background rates expected, for example, in the muon spectrometer of a detector for the Future Circular Hadron Collider (FCC-hh), in partic...    »
 
Translated abstract:
Nach der Luminositätssteigerung des Large Hadron Colliders (HL-LHC) wird durch die höheren Untergrundraten die Ratenfähigkeit der Myondriftrohrdetektoren des ATLAS-Experiments überschritten werden, weshalb neuartige Driftrohrkammern mit kleinerem Rohrdurchmesser (sMDT) entwickelt wurden. Es wurde die Ratenfähigkeit der sMDT-Kammern bis zu noch höheren Untergrundraten, wie sie zum Beispiel im Myonspektrometer eines Detektors am Future Circular Hadron Collider (FCC-hh) erwartet werden, untersucht,...    »
 
Oral examination:
11.03.2020 
File size:
110575586 bytes 
Pages:
218 
Last change:
17.03.2020